Eaton 93PM UPS

In stock

Product snapshot

POWER RATING

10-400kW

VOLTAGES

480V, 415V, 400V, 380V, 220V, 208V

FREQUENCY

50/60 Hz

TOPOLOGY

Double conversion with optional Energy Saver System (ESS)

EFFICIENCY

Up to 97% in double conversion

Up to 99% in Energy Saver System

SCALABILITY

480V model: up to 8 internal power modules

208/220V model: up to 10 internal power modules

External parallel up to 8 UPSs

CONFIGURATION

Tower

BATTERIES

480V model: Internal batteries up to 50kW

415/400/380V model: Internal batteries up to 40kW

208/220V model: Internal batteries up to 60kW

External battery options for all models

Full tech specs

Power modules

POWER OFFERING (KW)

10–200 kW in 5 kW increments at 208/220V

20–160 kW in 10 kW increments at 415/400/380V

20–200 kW in 10 kW increments at 480V

200–400 kW in 50 kW increments at 480V

Note: optional internal redundancy available for all models

General characteristics

EFFICIENCY IN ENERGY SAVER SYSTEM (ESS)

Up to 99%

EFFICIENCY IN DOUBLE-CONVERSION MODE

Up to 97%

PARALLEL CAPABILITY

Up to eight distributed. Some restrictions may apply; contact factory for more information.

Input characteristics 480V models 400V models 208V models
Voltage 480/277V 4-wire
480V 3-wire
380/220V 4-wire
400/230V 4-wire
415/240V 4-wire
208/120V 4-wire
220/127V 4-wire
Voltage range: +10%/-15% +10%/-10% +15%/-15% @ 208V

+10%/-15% @ 220V

Frequency range 50/60 Hz 50/60 Hz 50/60 Hz
Power factor > .99 > .99 > .99
Input current distortion < 3% @ 100% load capacity < 3% @ 100% load capacity ≤ 3.5% @ 100% load capacity
Battery options 480V models 400V models 208V models
Battery voltage 432V, 480V 480V 480V
Charging method ABM® or float technology ABM® or float technology ABM® or float technology
Battery type VRLA, AGM, Gel, Wet, Lithium, Flywheel, Super Caps VRLA, AGM, Gel, Wet, Lithium, Flywheel, Super Caps VRLA, AGM, Gel, Wet, Lithium
Output 480V models 400V models 208V models
Voltage 480 3-phase3-wire or 4-wire

208/120V with optional IAC-D, up to 200 kW

380V, 400V or
415V 3-phase
3-wire or 4-wire
208V or 220V 3-phase 3-wire or 4-wire
Frequency range 50/60 Hz 50/60 Hz 50/60 Hz
Regulation ±1% steady state ±1% steady state ±1% steady state
Voltage THD < 1% (100% linear load)
< 5% (non-linear load)
< 1% (100% linear load)
< 5% (non-linear load)
< 1% (100% linear load)
< 5% (non-linear load)
Load power factor range Unity with the ability to support 0.8 leading to 0.8 lagging without de-rating Unity with the ability to support 0.8 leading to 0.8 lagging without de-rating Unity with the ability to support 0.8 leading to 0.8 lagging without de-rating
Certification 480V models 400V models 208V models
Safety UL 1778, cULus, UL 924 Emergency, UL 924 Auxiliary UL 1778, cULus UL 1778, cULus
EMC FCC Part 15 subpart B class A FCC Part 15 subpart B class A FCC Part 15 subpart B class A
Surge IEC 61000-4-5 IEC 61000-4-5 IEC 61000-4-5

UPS DIMENSIONS

Height: 74"

Depth: 42"

Width:

22”

  • 20–150 kW (480V)\
  • 20-120 kW (400V)
  • 10–120 kW (208/220V)

32”

  • 160–200 kW (480V)
  • 120-160 kW (400V)

34.4"

  • 10–160 kW (208/220V)

43.3"

  • 10–200 kW (208/220V)

64"

  • 250–400 kW (480V)

 

UL 924 CERTIFICATION

The 93PM meets the strict standards for UL 924 compliance for emergency lighting applications when ordered with an emergency lighting SKU. For more information, visit Eaton.com/UL924UPS.

OPTIONAL ACCESSORIES

• Integrated maintenance bypass
• Integrated distribution cabinet (with input and output transformer options)
• Integrated power distribution cabinet
• Integrated parallel tie cabinets
• Integrated battery cabinet (small and large)
• Wall-mounted or floor mounted bypass
• Lithium battery cabinet
• Custom options available. Contact factory for more information.

 

Compare
Category:

Eaton 93PM UPS

The Eaton 93PM UPS is the perfect three-phase white or gray space solution for modern data centers. The 93PM is compatible with lithium-ion UPS batteries, which are 40 percent smaller than VRLA batteries and have twice the lifespan, saving money on battery replacement costs and extra square footage for battery cabinets. The option of front-to-back or front-to-top ventilation maximizes deployment flexibility and lowers your cooling costs. In addition, you can add a number of optional, full integrated accessories for a complete system, including a maintenance bypass, a distribution cabinet (with input and output transformer options), a power distribution cabinet, parallel tie cabinets and battery cabinets as well as a wall-mounted or floor mounted bypass. Whether for a large data center, medical facility or educational institution, the efficiency provided by the 93PM can play a vital role in any low maintenance, ten-year power solution.
POWER RATING
10-400 kW
VOLTAGES
480V, 415V, 400V, 380V, 220V, 208V
CONFIGURATION
Tower

Easy deployment

● Maximizes deployment flexibility with thermal management options, flexible configurability and full-service access from the front
● Simplifies installation by fitting perfectly in line or alongside any standard-depth rack

Ease of management

● Provides easier access to detailed status information
● Optimizes server virtualization through power management and connectivity software
● Increases uptime with 24×7 remote monitoring and reporting capabilities

Lowest Total Cost of Ownership (TCO)

● Reduces power and cooling
● Conserves valuable data center floor space
● Reduces cost and unexpected future growth risks

Main Menu